FAQs

For more than two decades we’ve been supporting designers to incorporate our solutions into their products. Here are some of the most commonly asked questions about CambridgeIC – if you have a question that we don’t answer below, please contact us!

What is CambridgeIC’s position sensing solution?

It comprises a moving, contactless target and a fixed sensor.  The sensor is connected to processing circuitry including a processor such as the CAM622.  This detects the position of the target relative to the sensor and reports measurement results to a host device.

The sensor comprises coils printed on a PCB, making it easy to manufacture.  CambridgeIC has a large library of standard designs that customers can use free of charge, providing they are only used with a CambridgeIC processor IC.  Our newest Type B range of sensors works with targets also manufactured from PCBs.

This approach yields:

  • Accurate, absolute, high-resolution position measurements, that are
  • Highly tolerant of misalignment and a wide gap range,
  • Immunity to harsh environments,
  • Immunity to mechanical vibration and shocks, and
  • Deep integration into a customer’s electromechanical product to offer significant cost savings
How does it work?

Resonant inductive position sensing measures the position of a target relative to a sensor.  The target includes inductor coil(s) connected to resonating capacitor(s), forming a resonant circuit that inductively couples to coils printed on the sensor.

The sensor’s coils include an excitation coil and one or more pairs of COS/SIN patterned sensor coils, and these are connected to the processing circuitry including a CambridgeIC processor IC.

To take a measurement this circuitry first applies a burst of AC current to the excitation coil (the pulse).  Its frequency matches the target resonator’s frequency, forcing it to resonate in response.  The excitation current is then removed and the target’s resonance begins to decay.  While it decays, the processor detects the EMFs that it induces in the sensor coils (the echo).  The processor calculates position from the relative amplitudes of signals detected in one or more pairs of sensor coils.

More details are available in the Technology section and in the Type B Sensor Reference Manual.

Why use a resonant target and not just a metal one like in a standard inductive sensor?

By using a resonant target with a high Q-factor, the target returns far more signal to the sensor, dramatically improving resolution, even with large gaps between the sensor and target.

Why use pulse echo interrogation and not just excite continuously like in a standard inductive sensor?

By separating the pulse and echo phases of interrogation, the system ensures that the excitation current does not disturb the measurement process.  This dramatically improves performance, eliminates the need for calibration and allows designers to site the sensor remotely from the processor.

What is a CTU?

CambridgeIC’s first generation of processors including the CA204, CAM502 and CAM312 are referred to as Central Tracking Units (CTUs)

Are CambridgeIC solutions affected by electromagnetic fields? (EMC)

Generally our solution is not sensitive to AC magnetic fields as sensor coils are balanced, meaning interference tends to affect both coils equally. The sensor operating frequency is low (centered around 187.5kHz for our CTU ICs and 833.3kHz for the CAM622).

This is higher than motor driver frequencies and their significant harmonics, which explains why we do not have any reports of interference from motors. On the other hand it is much lower than frequencies that typically cause EMC issues, and these are removed with low-pass filters. Detected signal levels are high (typically a volt) so any residual interference is insignificant compared to sensor signals.

Are CambridgeIC’s position sensors truly absolute?

Yes, no movement is needed on power up and measurements will be the same before and after power up.

Is the solution affected by metal nearby?

Our technology is far more immune to nearby metal than standard inductive sensors, because it detects a resonator which has a unique electronic signature and not just another piece of metal.

We recommend that metals are not in contact with the sensor – a gap of 3mm to aluminium is typically sufficient to avoid compromising performance. Please refer to the relevant sensor datasheet for more on integrating that sensor and its target near metal, and for Type B sensors to the Type B Sensor Reference Manual.

Please contact us for any additional guidance on integration with metal that is required.

Will dirt or moisture affect the position sensor?

CambridgeIC solutions are inherently tolerant of harsh conditions and are insensitive to dirt, shock and vibration. In applications where the sensor may be directly exposed to condensing moisture or immersed in fluids, the sensor and target should be mounted inside a housing or coated. Most sensors can be operated with a big gap to the target, which means it is possible to separately encapsulate the sensor and target. This means there is no need to seal both inside the same enclosure. This in turn means there is no need for sliding seals, which often add considerable cost and complexity when other sensor technologies are used.

What is the maximum distance between target and sensor?

CambridgeIC’s solution can allow for quite large and variable gaps between sensor and target. Depending on resolution required, gaps of up to 4mm are typically possible, allowing space for encapsulation.  Please refer to individual sensor datasheets or contact us.

Can I use it in marine environments?

Yes, we have a number of marine and submarine applications including instruments on yachts, submersibles and ROVs.

Is a CambridgeIC solution suitable for high volume applications?

Yes, since the sensor design can be deeply integrated into a product, giving both flexibility and cost reduction. Further, customers arrange sensor manufacture at their normal PCB fab, bringing control over pricing and quality.

What are Type B Sensors?

Type B Linear Sensors and Type B Rotary Sensors are designed to work with the CAM622.  Their respective targets are tuned to a higher resonant frequency (centered around 833.3kHz) than CambridgeIC’s CTU ICs (centered around 187.5kHz).  This means:

  • Targets for Type B sensors can be built from PCBs, like their matching sensors, decreasing cost and space requirements, and
  • The CAM622’s measurement rate can be far higher (33,000 measurements per second)
How many sensors can be read by a single processor IC?

CambridgeIC sells a range of processor ICs, differing in speed and the number of sensors that can be connected.

CambridgeIC’s CAM622 is optimised for speed and therefore only connects to one sensor.

For CambridgeIC’s older generation of CTU processors, the number depends on Type of circuitry used (see ‘what is the differences between type 1, 2, 3, 4 and 6 circuitry?’ below):

Sensor Category Basic Precision
Circuitry Type 1 or 4 Type 2 Type 3 Type 6
CAM312 ≤2 1 1 1
CAM502 – 1 – 1
CAM204 ≤4 1 – ≤2

 

What is the difference between Type 1, 2, 3, 4 and 6 circuitry?

Sensors can have different number of coils, arranged in several ways, which make them more suitable for some applications than others. We classify these differences in design into types:

Circuitry Type Number of coils Application
Excitation Detection
1 1 2 Basic linear and rotary sensors (0V is EX return, VREF is sensor common return)
2 1 4 Long precision linear sensors
3 4 Linear Axial sensors with target freely rotating around measuring direction
4 1 2 Basic linear and rotary sensors (VREF is common)
6 1 4 Precision linear and rotary sensors

 

What is a sensor's Subtype?

A precision sensor’s Subtype is the number of fine COS/SIN sensor coil periods per coarse period.  For example a 25mm B3 Rotary Sensor has main Type B, Subtype 3, and that number 3 refers to 3 COS/SIN repeats around a circle for one coarse COS/SIN repeat.  Larger rotary sensors and longer linear sensors tend to have a larger Subtype since it’s possible to fit more fine periods along the measuring range.

Basic sensors don’t have fine sensor coils.  Basic Type B sensors are described as “B0” with the 0 indicating no fine coils.

What is Noise Free Resolution?

Noise Free Resolution is actual resolving power: how close two different measurement values can be for the system to reliably tell them apart.

Measurements are fundamentally analog and include noise.  In order for a system to resolve two different values, they must be separated by at least the peak to peak noise.  When noise is approximately gaussian, like it is for resonant inductive sensors:

Peak to Peak Noise = 6.6 x Standard Deviation

The factor 6.6 puts peak to peak noise at 6.6 standard deviations, so that statistically only 1 in 1000 measurements will fall outside the range.  Standard Deviation is a more reliable measure of noise than directly measuring peak to peak.

This expression works for both linear sensors (noise in mm, say) and rotary (noise in °).

Noise Free Resolution is often expressed in bits instead, based on:

Noise Free Resolution = log2 (Measuring Range / Peak to Peak Noise)

Noise Free Resolution is closely related to measurement bandwidth.  In general, measurements taken from a high-bandwidth system can be processed (low pass filtered) to a smaller bandwidth in order to improve Noise Free Resolution.  The CAM622 includes a configurable, adaptive low-pass filter which improves Noise Free Resolution by up to 3 bits.

Many competitors choose to instead quote only Interface Resolution, and refer to this alone as “Resolution”.  In some instances the difference can be over 12 bits!  We choose to focus on Noise Free Resolution because that most closely matches what customers are trying to achieve: resolving between different values.

What is the best achievable noise free resolution?

The 108mm Type B Rotary Sensor delivers the highest Noise Free Resolution: 18 bits at 1mm gap and default CAM622 motion filter settings.

Remember this really is Noise Free Resolution.  The Interface Resolution is 32 bits over SPI or BiSS, or 24 bits over SENT.

What is the best achievable accuracy?

The 180mm Type B Rotary Sensor typically delivers better than ±0.01° linearity error when aligned at 1mm gap.

Even with gap up to 4mm, ±0.5mm radial misalignment and ±0.1° of tilt error, this sensor still delivers ±0.023° linearity error.  Its immunity to misalignment is 22 times better than an optical or magnetic encoder with the same code disc diameter!

Are there any size limits?

Our sensor designs are for embedding inside products, and sizes reflect this.

The smallest standard rotary sensor is 21mm diameter.

The smallest linear sensor has a measuring length of 5mm.

The largest standard rotary sensor has a diameter of 180mm.

The longest standard linear sensor has a measuring length of 500mm. We have done custom designs up to 2m.

How can I test the performance of a CambridgeIC solution?

The simplest way to get started with CambridgeIC solutions is to contact us with your design challenge and we can help you check which sensor design would be most suitable for evaluation.  We can also help advise the best tools and accessories, to get the system up and running quickly and with low effort.

For new designs the best place to start is with a Type B Rotary Sensor and its matching Type B Rotary Target or a Type B Linear Sensor and its matching Type B Linear Target, and the MultiComms Bundle.  This connects to a PC running CambridgeIC’s CAM622 Read Position or CAM622 Configuration Tool applications.

How can I mount a sensor or target when it doesn't have any mounting holes?

CambridgeIC often supplies sensor and target samples without mounting holes, in order to minimise board area and hence make them as universally usable as possible.  For evaluation purposes please use glue, for example epoxy.

For production, customers build their own sensor PCBs (and usually Target PCBs too, depending on the design).  Customers may extend the board outline and add suitable mounting features such as holes for screws or clips.

For linear sensing there is an example shown on the linear motor control page, where both sensor and target board outlines are extended to make space for holes.

Another linear example on the linear actuator page shows how a linear sensor PCB’s width can be increased so that it can be mounted by sliding it into slots in an aluminium extrusion.

How can I design CambridgeIC solutions into my product?

CambridgeIC has developed a range of standard sensor designs (including linear, rotary and arc sensors) which can be built using conventional PCB processes by any competent PCB manufacturer. We can supply PCB blueprints for your PCB designer, so sensor designs can be built into a board that can also support other electronic circuitry.

For prototyping we can also sell assembled sensor samples.

I have a size/mechanical arrangement that is not covered by the off the shelf designs - can I get a custom design?

Please contact us to discuss.